Add to Cart
Fast Shipping 0.5T Oil Fired Steam Boiler With 1.0MPa Work Pressure
1. Adopting 3-passes, corrugated fire tube, wet back design; gets more than 95% high thermal efficiency.
2. Equipped with finned tube type condenser to re-use the heat in exhaust gas;
3. Adopting new heat insulating material and high quality steel plate to pack the boiler,good thermal insulation effect and nice looking ;
4. Its novel design, rational structural and nice performance achieved perfect quality and nice performance;
5. The openable front/back smokebox make the inspection & maintenance is easier;
6. Under the commanding of PLC, all auxiliaries work automatically and safely;
7. Compact structure not only makes the installation is easy, also reduce the construction cost of boiler room,high efficiency,less pollution ,low noise.
Product Name |
Oil Fired Steam Boiler
|
Fuel Type |
Diesel, Crude Oil, Fuel Oil
|
Thermal Efficiency |
95%
|
Operation Control |
PLC Programmable Control
|
Structure |
Horizontal,3-Passes,Wet-back,Corrugated Fire Tubes
|
After-sales Service Provided |
Engineers Available To Service Machinery Overseas
|
Corrugated Furnace,3 Fire-Passes/ Wetback
increase boiler's heat surface, improve energy efficiency
Mechanical Insulation Package
makes the insulation tighter for better thermal insulation
Finned Exhaust Condenser
re-use the latent heat of exhaust gas, heat the feedwater
Steam Boiler Model
Item Unit Model | WNS 0.5-1.0 -Y(Q) | WNS 1- 1.0 -Y(Q) | WNS 1- 1.25 -Y(Q) | WNS 1.5- 1.0 -Y(Q) | WNS 2- 1.0 -Y(Q) | WNS 2- 1.25 -Y(Q) | WNS 3- 1.25 -Y(Q) | WNS 4- 1.25 -Y(Q) | WNS 6- 1.25 -Y(Q) | WNS 8- 1.25 -Y(Q) | WNS 10- 1.25 -Y(Q) | WNS 15- 1.25 -Y(Q) | WNS 20- 1.25 -Y(Q) | ||
Rated Capacity | t | 0.5 | 1 | 1 | 1.5 | 2 | 2 | 3 | 4 | 6 | 8 | 10 | 15 | 20 | |
Feedwater Temp | ℃ | 20 | |||||||||||||
Steam Pressure | MPa | 1.0 | 1.0 | 1.25 | 1.0 | 1.0 | 1.25 | ||||||||
Steam Temperature | ℃ | 183.2 | 183.2 | 194 | 183.2 | 183.2 | 194 | ||||||||
Heating Surface | ㎡ | 25.1 | 35.2 | 36.4 | 53.55 | 73.1 | 68 | 106.7 | 141.5 | 185.8 | 261.8 | 351.1 | 513.9 | 616.7 | |
Thermal Efficiency | % | 95%-99% | |||||||||||||
Fuel Consumption | Diesel | Kg/h | 31 | 67 | 69 | 101.6 | 132.6 | 133.7 | 198 | 280.1 | 386.1 | 550 | 681 | 1020.8 | 1372.2 |
Gas | Nm³/h | 38.2 | 72 | 72 | 108 | 144 | 144 | 216 | 288 | 432 | 572 | 718 | 1076 | 1410 | |
Power Consumption | KW | 3.2 | 5 | 5 | 6 | 7 | 7 | 15 | 15 | 20 | 26 | 40 | 55 | 65 | |
Boiler Weight | t | 3.5 | 4.8 | 5.3 | 5.9 | 6.8 | 7.2 | 9.1 | 12.3 | 16.2 | 19.6 | 27.4 | 38 | 47 | |
Water Volume | m³ | 1.8 | 2.8 | 2.8 | 3.6 | 3.9 | 3.9 | 6.3 | 8.5 | 9 | 13.3 | 13.6 | 23.5 | 32.3 | |
External Dimension | L | mm | 2954 | 3000 | 3300 | 3400 | 3800 | 3800 | 4300 | 4580 | 5300 | 6254 | 6373 | 7415 | 7830 |
W | mm | 1394 | 1760 | 1760 | 2050 | 2000 | 2000 | 2050 | 2280 | 2380 | 2528 | 2640 | 3360 | 3500 | |
H | mm | 1752 | 2100 | 2150 | 2250 | 2200 | 2350 | 2550 | 2550 | 2645 | 3015 | 3124 | 3510 | 3998 | |
Live Steam Pipe | mm | 50 | 50 | 50 | 65 | 80 | 80 | 80 | 100 | 125 | 150 | 150 | 200 | 250 | |
Water Inlet Pipe | mm | 25 | 25 | 25 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 65 | |
Relief Valve Pipe | mm | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 65 | 80 | 80 | 100 | 100 | |
Drain Pipe | mm | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 50 | 50 | |
Chimney | mm | 300 | 300 | 300 | 300 | 350 | 350 | 400 | 400 | 600 | 700 | 800 | 900 | 1000 | |
Basement | L | mm | 2240 | 2835 | 2835 | 2900 | 3100 | 3100 | 3360 | 3560 | 4100 | 5200 | 5380 | 6180 | 6800 |
W | mm | 950 | 1100 | 1100 | 1200 | 1200 | 1200 | 1450 | 1500 | 1750 | 2000 | 2100 | 2300 | 2650 | |
Transport Size | L | mm | 2954 | 3254 | 3254 | 3442 | 3886 | 4002 | 4260 | 4794 | 5372 | 6646 | 6882 | 7407 | 8166 |
W | mm | 1556 | 1770 | 1770 | 1900 | 1900 | 1900 | 2130 | 2180 | 2198 | 2600 | 2600 | 3193 | 3400 | |
H | mm | 1727 | 2072 | 2072 | 2159 | 2172 | 2177 | 2425 | 2502 | 2635 | 3043 | 3246 | 3553 | 4027 |
Prodects Show